The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Building code glass doors.
Glass sloped 15 degrees 0 26 rad or less from vertical in windows curtain and window walls doors and other exterior applications shall be designed to resist the wind loads due to ultimate design wind speed v ult in section 1609 for components and cladding.
According to the 2012 international residential code it is required at these hazardous locations.
The florida building code is divided into eight major sections.
By heating glass at a high temperature then rapidly.
Residential building codes for safety glass.
The massachusetts state building code consists of a series of international model codes and any state specific amendments adopted by the board of building regulation and standards bbrs.
Anywhere within 5 of a hot tub swimming pool spa sauna shower or bathtub.
Tempered glass is made to reduce the chances of injury or death.
Mullions the 2018 irc requires window mullions to undergo testing or structural calculations to demonstrate the ability to meet structural requirements.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Exceptions may be made for openings less than 3 inches in diameter in doors or decorative glass and glazing provided with a protective bar.
Glass doors by definition in the iecc are considered to be those which are more than 50 percent glass in area.
So for all these reasons the international residential code irc and residential edition of the florida building code fbc r302 5 have safety standards for a door that separates the garage from the house interior.
When glass breaks it often forms large dangerous shards that can pose significant safety risks.
Building codes for exterior doors.
The u factor requirements discussed above for vertical fenestration also apply to exterior glass doors.
If the door is equal to or less than 50 percent glass it is considered to be an opaque door.
If you are planning to replace a door or window you must first comply with the existing building section.
The sections that apply to the replacement of a door or window are building residential existing building and energy.
Anything within 2 of a door on the hinge side.
The door cannot open directly onto a room used for sleeping purposes bedroom and must be one of the following types.
Glass in glazed curtain walls glazed storefronts and glazed partitions shall meet the seismic requirements of asce 7 section 13 5 9.