For the 00 000 0000 etc.
Cable conductor size and current ratings.
Wire size chart and maximum amp ratings.
Current carrying capacity is defined as the amperage a conductor can carry before melting either the conductor or the insulation.
Wire size amp ratings.
Auto will automatically select the smallest cable that meets the three criteria for current rating voltage drop and fault current rating.
Where it is intended to group a cable in this table with other cables the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group see regulation 512 1 5.
Usually a general purpose house circuit is designed for 20 amps.
Select a cable size or select auto.
For the wiring of industrial buildings housing control.
2 calculate the size of the cable for the light of 120m distance long is to be lighted by 40w lamp.
High conductivity annealed stranded copper conductors to sans 1411 part 1.
The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient air temperature of 30 c 86 f.
1 current ratings for up to 1000 v pvc insulated single and multicore wiring cables ambient temperature up to 30 o c values for resistance are based on electrical resistivity for copper 1 724 x 10 8 ω m 0 0174 μω m and electrical resistivity for aluminum 2 65 x 10 8 ω m 0 0265 μω m.
Current carrying capacity of copper conductors.
1 determine the minimum size of cable with reference to the electrical installation regulation.
Cable is manufactured to sans 1507 part 3.
For cables having flexible conductors see section 2 4 of this appendix for adjustment factors for current carrying capacity and voltage drop.
The smallest awg size is 40 and the largest is 0000 4 0.
Pvc general purpose wire 1kv.
A 30m long twin pvc installation cable carrying current from a switch bulb in a domestic installation to a 4kv electric heater.
Awg wire sizes see chart below awg.
Insulated with pvc.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating.
The larger the awg number or wire guage the smaller the physical size of the wire.
Gauges you use 1 2 3 which makes more sense mathematically than double nought.
The higher the gauge number the smaller the diameter and the thinner the wire.
Ignore the neutral and earth conductor in three phase cables.
The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor.
Heat caused by an electrical current flowing through a conductor will determine the amount of current a wire will handle.
The number of cores in the cable.
The type of insulation.