So says the building code.
California building code shower doors.
Published july 1 2019.
This is because shower doors often are made of materials such as glass that can easily break and pose a danger.
The front of the toilet needs to have at least 21 inches of clearance.
Here are seven codes that you should know.
The minimum interior shower size is 30x30 inches or 900 square inches in which a disc 30 inches in diameter must fit.
Toilet bathroom building codes.
Effective january 1 2020.
Any doors shall swing out of the enclosure have a clear opening of 22 inches minimum.
The building codes of california adopt the the california administrative code 2019 california building code 2019 california residential code 2019 california mechanical code 2019 california plumbing code 2019 california energy code 2019 california historical building code 2019 california fire code 2019 california existing building code 2019 california green building standards code 2019.
Shower sizing different municipalities may impose minimum shower sizes but many stick to the california building code.
Shower maximum sizes are not mandated but minimum sizes are regulated.
The distance from the centerline of a toilet and or bidet to any bath fixture wall or other obstacle should be at least 18 inches.
2019 california building standards code title 24 education outreach.
Shower floor minimum size is usually mandated to be at least 30 inches square.
Cbc 1210 and crc r307 2.
Glass sloped 15 degrees 0 26 rad or less from vertical in windows curtain and window walls doors and other exterior applications shall be designed to resist the wind loads due to ultimate design wind speed v ult in section 1609 for components and cladding.
Safety glazing is required at all windows that are less than 60 above the bottom of tub shower floors at tub shower enclosure panels doors check for bug crc r308 4 cbc 2406 2 2406 4 fixture fittings attachments vacuum breakers are required for handheld shower heads.
Many cities and communities require the toilets to have water conserving devices.
Cpc 408 5 408 6 shower stalls and bathtubs with shower heads installed shall have walls finished with a non absorbent surface for a minimum of 6 feet above the floor.
Glass in glazed curtain walls glazed storefronts and glazed partitions shall meet the seismic requirements of asce 7 section 13 5 9.
1 mental penal or corrective institutions where supervisory personnel is continually on duty and effective provisions are made to remove occupants in case of fire or other.
For instance according to the city of berkeley your shower needs to be at least 1 024 square inches which is equivalent to a square space with 32 inch sides.
That is 30 inches by 30 inches.
Because shower doors are usually glass and can break and because of other access issues bathroom code states that shower doors need to have at least 24 inches of.